Back-UPS®RS 700 Installation & Operation Overview Connect the battery Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Do not connect a laser printer or hair dryer to the unit. Ensure that the connected equipment does not exceed the maximum load. Front panel Rear Panel.
®
Caution
• For safety, the Back-UPS ES is shippedwith one battery wire disconnected. Small sparks may occur during battery
Apc Backup Software
• Do not install the unit in direct sunlight, in excessive heat or humidity, or in contact with fluids.
•Connectthepower cord directlytoa wall outlet; not a surge protector or power strip. The outlet
must be located near the equipment and easily accessible.
Overview
Press the ON/OFF switch to turn the unit ON. A single short beep and the green “Power On” indicator confirms that
Back-UPS ES is on and ready to provide protection. The UPS will automatically perform a self-test when power is
applied tothe unit, the green LED will flash during the self-test.
Note: Prior to first use, charge the Back-UPS for at least 16 hours to ensure sufficient runtime. The unit is charging
whenever it is connectedto utility power, whether the unit is turned ON or OFF.
Master Outlet—Connect a master device, such as a computer. See
2
Battery Backup and Surge Protection—These outlets receive
power whenever the unit is ON. During a power outage or other
utility problems (brownouts, over-voltages), these outlets will
receivepower from the unit for a limited time. Connect a computer,
monitor, and two other data-sensitive devicesinto these outlets.
Note that one of these outlets is the Master outlet. See “Using the
3
Controlled Outlets—Connect peripheral devices. See “Using the
4
Surge Protection—These outlets provide full-time protection from
surges even if the unit is OFF, but will only supply power when the
unit is ON. Connect a printer, fax machine, scanner, or other
peripherals that donot need battery power during power outages.
Note that if the power-saving feature is enabled, three of these
5
Data Port—Use the supplied RJ45/USB cable to connect the Back-
UPS unit to a computer to install the software. See “Install the
6
Circuit Breaker—Push to re-set the circuit breaker.
Modem/Phone/Fax—Connect a DSL or dial-up modem, phone,
fax machine, or 10/100 Base-T ethernet equipment. Note: Donot
Apc Back Ups 600 Manual
connect the UPS telephone protection ports to both the
telephone and network system cables at the same time.
Apc Back Ups Pro 700 Software
Wall outlet—Connect the unit to a data line wall outlet.